Amending Rule II and Rule V, Section 19 Item I of the Implementing Rules and Regulations of B.P. 220
On January 28, 2009, the Housing and Land Use Regulatory Board (HLURB) issued Administrative Order No. 001-09, implementing amendments to various sections of the Implementing Rules and Regulations of B.P. 220. The changes, as per HLURB Board Resolution No. R-824, aim to update technical standards and design parameters for economic and socialized housing projects to align with the Fire Code and National Building Code. Key amendments include specifications on minimum lot areas, frontages, and building design standards, particularly regarding firewalls and parking requirements. These amendments are effective 15 days following their publication in the Philippine Daily Inquirer on January 27, 2009.
January 28, 2009
HLURB ADMINISTRATIVE ORDER NO. 001-09
| TO | : | All Concerned |
| SUBJECT | : | Resolution No. R-824, s. 2008, Amending Rule II, Section 5.C.2.B and c, Section 6.A.2.h, Section 6.B.1.g and Section 6.B.2.a-b and c.6 and Section 19 Item j and Deleting Section 6.A.2.f and Rule V, Section 19 Item I of the Implementing Rules and Regulations of B.P. 220 |
Attached herewith is HLURB Board Resolution No. R-824, Series of 2008, Amending Rule II, Section 5.C.2.b and c, Section 6.A.2.h, Section 6.B.1.g and Section 6.B.2.a-b and c.6 and Section 19 Item j and Deleting Section 6.A.2.f and RULE V, Section 19 Item I of the Implementing Rules and Regulations of B.P. 220, which was approved by the Board on 12 November 2008.
The above was published in The Philippine Daily Inquirer on 27 January 2009, and, in accordance with the provisions of law, shall take effect on 11 February 2009, fifteen (15) days from its date of publication.
Please be guided accordingly.
Adopted: January 28, 2009
Date Filed: February 1, 2010
(SGD.) ROMULO Q.M. FABULCommissioner and Chief Executive OfficerHousing and Land Use Regulatory Board
HLURB Board Resolution No. 824,
AMENDING RULE II, SECTION 5.C.2.B AND C, SECTION 6.A.2.H, SECTION 6.B.1.G AND SECTION 6.B.2.A-B AND C.6 AND SECTION 19 ITEM J AND DELETING SECTION 6.A.2.F AND RULE V, SECTION 19 ITEM I OF THE IMPLEMENTING RULES AND REGULATIONS OF BP 220
WHEREAS, under BP 220 the Housing and Land Use Regulatory Board is mandated to establish and promulgate different levels of standards and technical requirements for economic and socialized housing projects in urban and rural areas from those provided under PD 957, PD 1216, PD 1096 and PD 1185; HTCISE
WHEREAS, there is a need to review the standards under BP 220 in relation to the provisions of the Fire Code and the National Building Code to uphold the spirit of BP 220 towards promoting cost efficient production of affordable socialized and low cost housing;
WHEREFORE, resolved as it is hereby resolved that the following provisions of the Implementing Rules and Regulations to Implement BP 220 be AMENDED to read as follows:
"Section 5. Technical Guidelines and Standards for Subdivisions. —
xxx xxx xxx
A. Site Criteria
xxx xxx xxx
C. Design Parameters
1. Land allocation
xxx xxx xxx
2. Lot requirement
a. Lot planning
xxx xxx xxx
b. Minimum lot area
The minimum lot area of various types of housing for economic and socialized housing project shall be as follows:
Table 7. Minimum Lot Area
|
Type of Housing
|
Economic (sqm)
|
Socialized (sqm)
|
|
|
|
|
|
|
| a. | Single detached |
72
|
64
|
| b. | Duplex/single attached |
54
|
48
|
| c. | Row houses |
36
|
28
|
Note:
1. Saleable lots designated as duplex/single attached and/or row house lots shall be provided with housing components.
2. Price of saleable lots intended for single detached units shall not exceed 40% of the maximum selling price of the house and lot package.
c. Lot frontages
The minimum lot frontages for various types of housing both for economic and socialized housing projects shall be as follows:
Table 8. Minimum Lot Frontage
|
Type of
|
Economic
|
Socialized
|
||
|
Housing/Lot
|
Housing
|
Housing
|
||
| 1. | Single detached | |||
| a. | Corner lot |
8m
|
8m
|
|
| b. | Regular lot |
8m
|
8m
|
|
| c. | Irregular lot |
4m
|
4m
|
|
| d. | Interior lot |
3m
|
3m
|
|
| 2. | Duplex/single attached |
6m
|
6m
|
|
| 3. | Row house |
4m
|
3.5m
|
Note:
For row houses, there shall be a maximum of 20 units per block or cluster but in no case shall this be more than 100 meters in length.
xxx xxx xxx
Table 9. Planning and Design Standards for Residential Subdivision Project under BP 220
|
Parameters
|
|
|
Economic
|
Socialized
|
|
|
|
|
|
|
Housing
|
Housing
|
| 1. | Proper location |
xxx
|
xxx
|
||
| 2. | xxx |
xxx
|
xxx
|
||
| 3. | Minimum lot area |
|
|
||
| a. | Single detached |
72sqm
|
64sqm
|
||
| b. | Duplex/single attached |
54sqm
|
48sqm
|
||
| c. | Row house |
36sqm
|
28sqm
|
||
|
|
|
||||
| Saleable lots designated as duplex/single-attached |
|
||||
| and/or rowhouse lots shall be provided with |
|
||||
| housing components |
|
|
|||
| Price of saleable lots intended for single-detached |
|
||||
| units shall not exceed 40% of the maximum |
|
||||
| selling price for house and lot package. |
|
||||
|
|
|
||||
| 4. | Minimum lot frontage |
|
|
||
|
|
|
||||
| 4.1 | Single detached |
|
|
||
|
|
|
||||
| a. | Corner lot |
8m
|
8m
|
||
| b. | Regular lot |
8m
|
8m
|
||
| c. | Irregular lot |
4m
|
4m
|
||
| d. | Interior lot |
3m
|
3m
|
||
|
|
|
||||
| 4.2 | Single attached/duplex |
6m
|
6m
|
||
| 4.3 | Row house |
4m
|
3.5m
|
xxx xxx xxx
16. Setback/yard
| a. | front setback | 1.5m | |
| b. | side yard | 1.5m (from the building line) | |
| c. | rear yard | 2.0m | |
| d. | abutments | May be allowed per requirement of the | |
| National Building Code of the Philippines |
Section 6. Building Design Standards and Guidelines. —
xxx xxx xxx
A. Single Family Dwelling (Applicable for both Economic and Socialized Housing) aSITDC
1. Lot planning
xxx xxx xxx
2. Building Design Standards (Applicable for both Economic and Socialized Housing)
a. Space standards
xxx xxx xxx
f. Firewall
Whenever a dwelling abuts on a property line, a firewall shall be required. The firewall shall be of masonry construction, at least 150 millimeters or 6 inches thick and extend vertically from the lowest portion of the wall adjoining the living units up to a minimum height of 0.30 meter above the highest point of the roof attached to it. The firewall shall also extend horizontally up to a minimum distance of 0.30 meter beyond the outermost edge of the abutting living units.
A firewall shall be provided for duplex/single attached units and at every unit for rowhouses. No opening whatsoever shall be allowed except when the two abutting spaces of 2 adjacent living units are unenclosed or partially open, e.g., carports, terraces, patios, etc.; instead a separation wall shall be required. (See Figure 10: Firewall for dwelling units on property line).
Ceiling should be compartmentalized and should not be continuous from one living unit to another.
B. Multi-family dwellings and Condominiums (Applicable for both Economic and Socialized Housing)
1. Lot planning
a. Access to the property
xxx xxx xxx
g. Parking requirements
For multi-family dwellings and condominiums, the parking requirement shall be one (1) parking slot per eight (8) living units. The size of an average automobile (car) parking slot must be computed at 2.5 meters by 5.0 meters for perpendicular or diagonal parking and at 2.15 meters by 6.0 meters for parallel parking.
The driveway may be used as parking area provided that the minimum right-of-way shall be maintained. (see figure ___)
Off-site parking may be allowed in addition to on-site parking provided that the designated parking area is part of the project and provided further that it shall not be 100 meters away from the condominium project.
Mandatory compliance with additional parking space required by local ordinances.
2. Building Design Standards
a. Living units
In general, all building design standards for the single-family dwelling shall apply for all living units of multi-family dwellings, except that, the minimum floor area of a living unit in multi-family dwellings shall be 22 square meters for economic housing and 18 square meters for socialized housing. For BP 220 condominium projects, the minimum floor area shall be 18 square meters.
b. Exits, corridors, exterior exit balconies and common stairways
Standards for exits, corridors, exterior balconies and common stairways shall conform with the provisions of the National Building Code of the Philippines, and its implementing rules and regulations and as well as to Section 3.1007 of the Implementing Rules and Regulations of the Fire Code of the Philippines (Annex I). AIDcTE
Automatic fire alarm suppression system should be provided for structure more than 15 meters in height.
c. Utilities and services
xxx xxx xxx
c.6 elevator requirements (If applicable)
Provision of elevators shall be required for buildings 6 storeys and beyond. The same shall conform to the plans and specifications of the duly licensed architect/engineer who shall determine the requirement for elevators including the number of cars, capacity, safety features and standards, elevator type, speed and location in relation to the overall design and use of the building. The design architect/engineer shall certify under oath that all components thereof are in accordance with the National Building Code of the Philippines, Accessibility Law, National Industry Standards and other pertinent laws.
Compliance to the provisions of the Fire Code of the Philippines shall be mandatory.
xxx xxx xxx
Section 19. Definition of Terms. —
As used in these Rules, the following words and phrases are defined and understood to have the meaning correspondingly indicated therein.
xxx xxx xxx
i. Firewall — any wall which separates 2 abutting living units and extends vertically from the lowest portion of the wall which adjoins the 2 living units up to a minimum height of 0.30 meter above the highest portion of the roof attached to it; the firewall shall also extend horizontally up to a minimum distance beyond the outermost edge of the abutting living units."
xxx xxx xxx
Approve this 12th day of November 2008, Pasay City.
(SGD.) HON. NOLI L. DE CASTRO
(SGD.) ERNESTO L. PINEDA
(SGD.) ROMULO Q. FABUL
(SGD.) AUGUSTO B. SANTOS
(SGD.) TERESITA A. DESIERTO
(SGD.) AUSTERE A. PANADERO
(SGD.) JESUS YAP PANG
(SGD.) JOEL I. JACOB
(SGD.) ARTURO M. DUBLADO
Attested by:
(SGD.) CHARITO B. LANSANG